FAQ – Frequently Asked Questions
VVV-Group | Measuring Equipment
1. General Questions About the Company and Equipment
What does VVV-Group manufacture and supply?
The company specializes in professional measuring equipment, including:
-
Coating thickness gauges
-
Ultrasonic thickness gauges
-
Tint meters (glass light transmission meters)
-
Vibration meters
-
Diagnostic instruments for industrial and automotive applications
In which industries is the equipment used?
-
Automotive diagnostics
-
Industrial inspection
-
Non-destructive testing (NDT)
-
Energy sector
-
Service centers
-
Metal processing
-
Quality control and auditing
Does the equipment comply with international standards?
Most devices are designed in accordance with commonly recognized standards (ISO, ASTM, GOST — depending on the instrument type). Certification details should be verified for each specific model.
Is special training required?
Basic models are user-friendly and do not require formal technical education.
However, for industrial applications (especially ultrasonic testing and vibration analysis), operator training is recommended.
2. Coating Thickness Gauges (CM Series)
On which metals do the thickness gauges operate?
-
Ferromagnetic substrates (steel, iron)
-
Non-ferromagnetic substrates (aluminum, copper — FN models)
Is calibration required before use?
Yes. Zero calibration is mandatory before measurements to ensure accuracy.
Why do readings vary across different areas?
Possible reasons:
-
Coating thickness variation
-
Repaired sections
-
Filler material
-
Incorrect probe positioning
-
Measurements near edges
Can measurements be taken on dirty or wet surfaces?
No. The surface must be clean and dry.
How can repainting be detected?
Typical reference values:
-
Factory paint: usually 80–180 µm
-
Repainted surface: 200–400 µm
-
Filler material: 500+ µm
Exact values depend on the vehicle manufacturer.
3. Ultrasonic Thickness Gauges
What is the advantage of the ultrasonic method?
It allows thickness measurement from one side without damaging the material.
Can measurements be taken through paint?
Yes, if the device supports coating compensation mode. Basic models may require surface cleaning.
Why is couplant gel necessary?
The gel eliminates the air gap between the probe and the surface. Without it, measurement is not possible.
Why are readings unstable?
Possible causes:
-
Poor probe contact
-
Insufficient couplant
-
Rough surface
-
Incorrect sound velocity setting
Is it necessary to adjust the sound velocity?
Yes, if the material differs from standard steel. Incorrect velocity directly affects measurement accuracy.
4. Tint Meter (Light Transmission Meter)
What does VLT mean?
VLT (Visible Light Transmission) indicates the percentage of visible light passing through the glass.
Can factory-tinted glass be measured?
Yes. The device measures total light transmission, including factory tint.
Why do repeated measurements differ?
Possible reasons:
-
Misalignment of sensors
-
Dirty glass
-
Measurement in ceramic border area
-
Unstable positioning
Can laminated or double glass be measured?
Yes, but proper alignment of transmitter and receiver is required.
Does the device meet road inspection requirements?
This depends on the specific model and local regulations. Official inspections may require certified devices.
5. Vibration Meters
What parameter is better to measure — velocity or acceleration?
-
Velocity (mm/s RMS) — for general condition monitoring
-
Acceleration — for bearing condition evaluation
What values are considered critical?
For vibration velocity (general reference):
-
Below 2 mm/s — Good condition
-
2–4.5 mm/s — Acceptable
-
Above 7 mm/s — Requires diagnostics
Exact limits depend on equipment type and ISO standards.
Why measure in multiple directions?
Vibration has vector characteristics. Proper diagnostics require measurements:
-
Vertical
-
Horizontal
-
Axial
Can measurements be taken without a magnetic mount?
Yes, but measurement accuracy may decrease.
6. Accuracy and Calibration
What is the typical accuracy?
Depends on the model. Typical values:
-
Coating thickness gauges: ±(1–3%)
-
Ultrasonic thickness gauges: ±0.1 mm
-
Vibration meters: ±5%
-
Tint meters: ±2%
Refer to the specific model’s technical documentation.
Is annual verification required?
For commercial or official use, periodic verification may be required depending on local legislation.
Can calibration be performed independently?
Basic calibration — yes.
Official metrological verification must be performed by certified laboratories.
7. Operating Conditions
What is the operating temperature range?
Typically from +5°C to +40°C (refer to specific model specifications).
Can the equipment be used outdoors in winter?
It is possible, but measurement accuracy may decrease at low temperatures.
What should be done if an error appears on the display?
-
Restart the device
-
Check battery level
-
Perform recalibration
-
Check probe connection
8. Storage and Maintenance
How should the device be stored?
-
In a dry environment
-
Inside a protective case
-
With batteries removed during long-term storage
Do sensors require cleaning?
Yes. Especially:
-
Ultrasonic probes
-
Magnetic bases of vibration sensors
-
Optical windows of tint meters
Can the device be repaired independently?
Not recommended. Unauthorized repairs may void the warranty.
9. Warranty and Service
What is the warranty period?
Depends on the model and supplier. Typically 12 months.
What is not covered under warranty?
-
Mechanical damage
-
Water ingress
-
Improper use
-
Sensor damage
How can service be requested?
Contact the official supplier and provide:
-
Serial number
-
Description of the issue
-
Proof of purchase
10. Common Misconceptions
“More expensive means more accurate.”
Not necessarily. Proper calibration and correct methodology are more important.
“One measurement is enough.”
No. Reliable assessment requires multiple measurements.
“If the device turns on, it is ready.”
Not always. Most devices require calibration before use.
Conclusion
Measurement accuracy depends not only on the instrument but also on proper methodology.
Regular calibration, correct sensor positioning, and compliance with operating conditions are essential for reliable results.